  • 摘要: 以La(OH)3为共沉淀剂,使高纯Na2WO4中痕量Be、Sc、Yb、Zn与基体相分离并富集,然后用ICP-AES法测定.实验表明,当pH为12时,用6mL 1%La溶液进行两次共沉淀分离,能使上述元素定量分离回收.回收率为92.7%~102.5%,相对标准偏差为2.8%~5.9%.

     

    Abstract: ICP-AES has been developed for the simultaneous determination of trace beryllium, scandium, ytterbium and zinc in high purity sodium tungstate Coprecipitation of these elements with lathanum hydroxide was to separate the mfrom the matrix and for concentration It was found that the seelements could be satisfactory recovered after two times of coprecipitation with 6 mL lathanum solution (1%) at pH 12 0 The recoveries of them are in the range of 92 7%~102 5%, and RSD in 2 8%~5 9%.

     

/