药用丁基胶塞灰分的热重分析条件优化
Rapid Determination of Total Ash in Rubber Stoppers by Thermogravimetric Analysis
-
摘要: 针对药用丁基胶塞的灰分指标,考察了热重分析法的反应温度和恒温时间对测试结果的影响,优化了热重分析法测定胶塞灰分的检测方法. 方法测得的胶塞灰分值相对标准偏差为0.01%,且测试耗时少于1 h. 在缩短检测时间的同时,检测结果的准确性和重现性均优于用方法YBB00262005和方法ASTM D6370-99检测所获得的结果.Abstract: A rapid method to determine the total ash content in rubber stoppers is established using thermogravimetric analysis. The effect of different testing conditions on the results is studied as well. The relative standard deviation of the total ash obtained is 0.01% and the experimental time is less than 1h. The repeatability and accuracy of this method have been demonstrated better than that of YBB00262005 and ASTM D6370-99 methods.
-
张雪梅,董旭,徐飞. 丁基胶塞对大输液不溶性微粒的影响及解决方法[J]. 齐鲁药事,2011,30(4):241-242. 王国勤,吕贻胜,伍胜利. 药用包装卤化丁基胶塞的药物相容性及其发展趋势[J]. 中国包装,2010,7:49-51. 刘彬,钱夕霞,全红,等. 丁基胶塞清洗工艺对药品(粉针剂)澄清度的影响[J]. 河北化工,2007,5:52-54. 陆敏,徐娜,董诗成. 药用丁基胶塞产品质量主要影响因素的研究[J]. 安徽化工,2012,38(6):27-30. 国家食品药品监督管理局.YBB00262005 橡胶灰分测定法[S]. 全国橡胶与橡胶制品标准化技术委员会.GB/T 4498-1997 橡胶 灰分的测定[S]. 王备战. 对橡胶瓶塞炽灼残渣检查方法的二点看法[J]. 机电信息,2005,24: 54-55. 闫春芝,赵红彦. 对丁基胶塞灰分、针刺落屑及不溶性微粒的探讨[J]. 医药世界,2006,4:116-117. 朱艳梅,李昂,韩颖. 含氯橡胶灰分测定方法的研究[J]. 特种橡胶制品,1981,6:32-33. 赵艳芬. 橡胶灰分测定的不确定度评定[J]. 橡胶科技市场,2005,13:12-13. 美国材料与试验协会(US-ASTM).ASTM D6370-99(2003) 用热重力法对橡胶组成分析的标准试验方法[S]. -

计量
- 文章访问数: 2405
- HTML全文浏览量: 237
- PDF下载量: 44
- 被引次数: 0