分光光度法测定CO助燃剂中铂含量
Spectrophotometic Determination of Platinum in CO Combustion Improver
-
摘要: 建立了用分光光度法测定CO助燃剂中铂含量的方法. 在盐酸介质中,Pt(Ⅳ)被氯化亚锡溶液还原,生成黄色的亚氯铂酸(H2PtC14),最大吸收波长位于403 nm处. 方法简单、快捷、准确,回收率在97%~103%之间,相对标准偏差小于2.0%. 在优化的实验条件下,助燃剂中的常见元素对测定铂含量无干扰.Abstract: A method for the determination of platinum content in CO combustion improver using a spectrophotomeic method is described.In an HC1 medium, Pt(Ⅳ)was reduced by SnC12 solution and formed a yellow color chloroplatious acid(H2PtC14).The absorption maxima of which is at a wavelength of 403 nm.The method features simplicity,rapidness and accuracy,with a recovery in the range of 97% to 103%,and the relative standard deviations were less than 2%.The common elements existed in the CO combustion improver do not interfere the determination of platinum under the optimized test conditions.
-
Key words:
- combustion improver /
- platinum /
- spectrophotometry
-
陈强, 康敬万, 高锦章. 丁二酮肟络合吸附波测定微量铂[J].分析试验室, 2006, 25(2):97. 林海山.粗铜中铂的测定[J].冶金分析, 2004, 24(增刊):307. 夏至塾. 金铂喷丝头中铂的测定[J].黄金学报, 1999, 1(3):195. 中华人民共和国石油化工行业标准. SH/T0570-93重整催化剂铂含量测定法[S]. 王敏, 凌凤香. Pt/SiO2一Al2O3催化剂中铂含量测定的方法[J].理化检验-化学分册, 2008, 44(1):17-18. 王艳红, 张颖, 宫嘉辰.巯基棉分离体系用于铂钯废液中铂的测定[J].有色矿冶, 2012, 28(5):48-51. 张文利.电镀行业镀铂废水中铂的测定[J]. 科技信息, 2010, 19:366. 中国石油化工股份有限公司催化剂分公司企业标准. Q/SH349 930-2006催化重整催化剂化学组分的测定X-射线荧光光谱法[S]. -