极谱法测定地质样品中锡的方法改进

Improvement of Method for Determination of Tin in Geological Samples by Polarography

  • 摘要: 过氧化钠熔融分解样品,热水浸提,试样经铍盐做共沉淀剂,用乙二胺四乙酸(EDTA)消除钙、镁等的影响,在盐酸-氯化铵底液中,用极谱法对锡进行测定,改进并简化了国标方法. 对极谱法测定地质样品中锡从熔矿方式、测试温度以及干扰元素的影响及消除等方面进行探讨,并对仪器的工作条件进行优化. 锡的方法检出限为10.0 μg/g. 方法经标准物质验证,测定值与标准值相吻合,并进行不同仪器和方法的对比实验,结果一致,准确度高. 方法精密度(RSD,n=12)低于2%. 方法效率高、测定结果准确可靠,已应用于大量地质样品的分析中.

     

    Abstract: After the pretreatment of melting down in sodium peroxide, extracting with hot water, precipitating with beryllium salt, and eliminating the influence of calcium and magnesium with EDTA, tin in the samples were determined by polarography in a hydrochloric acid-ammonium chloride solution. This method improved and simplified the method described in the National Standards. The melting method, testing temperature and the interferential elements in the determination of tin in geological samples by polarography were discussed, and the working conditions of instrument were optimized.The detection limit of tin in this method was 10.0 μg/g. The measured values and standard values of the method were in reasonable agreement with analyzing the standard reference materials. The results from different instruments and methods were consistent.The method is highly accurate, with the precision(RSD,n=12)<2%. It has high efficiency, the measuring results were accurate and reliable. The method has been applied to the analysis of a large number of geological samples.

     

/