Determination of Vitamin B1 with Indicative Ion Cd2+ by Square Wave Polarography

  • A new method with Cd2+ as the indication ion, has been established for the determination of Vitamin B1 by using square polarography. No reduction wave of VB1 appeared in the buffer solution of NH3-NH4Cl. When Cd2+ was added to the above solution, the non-electro-active VB1 engendered a new peak at -0.360 V. The height of the peak is directly proportional to the concentration of VB1.The linear range of VB1 was 1.35 μg/mL~1.35 mg/mL and the determination limit was 0.13 μg/mL,r=0.9997. The mean recoveries was 99.6%(n=9), RSD=0.9%. This method is reliable,accurate and is very suitable for the determination of vitamin B1.